Publications by Year: 2001

2001

Westin C, Wigström L, Loock T, Sjöqvist L, Kikinis R, Knutsson H. Three-dimensional adaptive filtering in magnetic resonance angiography. J Magn Reson Imaging. 2001;14(1):63–71.
In order to enhance 3D image data from magnetic resonance angiography (MRA), a novel method based on the theory of multidimensional adaptive filtering has been developed. The purpose of the technique is to suppress image noise while enhancing important structures. The method is based on local structure estimation using six 3D orientation selective filters, followed by an adaptive filtering step controlled by the local structure information. The complete filtering procedure requires approximately 3 minutes of computational time on a standard workstation for a 256 x 256 x 64 data set. The method has been evaluated using a mathematical vessel model and in vivo MRA data (both phase contrast and time of flight (TOF)). 3D adaptive filtering results in a better delineation of small blood vessels and efficiently reduces the high-frequency noise. Depending on the data acquisition and the original data type, contrast-to-noise ratio (CNR) improvements of up to 179% (8.9 dB) were observed. 3D adaptive filtering may provide an alternative to prolonging the scan time or using contrast agents in MRA when the CNR is low.
Nabavi A, Black PM, Gering DT, Westin C, , Pergolizzi RS, Ferrant M, Warfield SK, Hata N, Schwartz RB, et al. Serial intraoperative magnetic resonance imaging of brain shift. Neurosurgery. 2001;48(4):787–97.
OBJECTIVE: A major shortcoming of image-guided navigational systems is the use of preoperatively acquired image data, which does not account for intraoperative changes in brain morphology. The occurrence of these surgically induced volumetric deformations ("brain shift") has been well established. Maximal measurements for surface and midline shifts have been reported. There has been no detailed analysis, however, of the changes that occur during surgery. The use of intraoperative magnetic resonance imaging provides a unique opportunity to obtain serial image data and characterize the time course of brain deformations during surgery. METHODS: The vertically open intraoperative magnetic resonance imaging system (SignaSP, 0.5 T; GE Medical Systems, Milwaukee, WI) permits access to the surgical field and allows multiple intraoperative image updates without the need to move the patient. We developed volumetric display software (the 3D Slicer) that allows quantitative analysis of the degree and direction of brain shift. For 25 patients, four or more intraoperative volumetric image acquisitions were extensively evaluated. RESULTS: Serial acquisitions allow comprehensive sequential descriptions of the direction and magnitude of intraoperative deformations. Brain shift occurs at various surgical stages and in different regions. Surface shift occurs throughout surgery and is mainly attributable to gravity. Subsurface shift occurs during resection and involves collapse of the resection cavity and intraparenchymal changes that are difficult to model. CONCLUSION: Brain shift is a continuous dynamic process that evolves differently in distinct brain regions. Therefore, only serial imaging or continuous data acquisition can provide consistently accurate image guidance. Furthermore, only serial intraoperative magnetic resonance imaging provides an accurate basis for the computational analysis of brain deformations, which might lead to an understanding and eventual simulation of brain shift for intraoperative guidance.
Gering DT, Nabavi A, Kikinis R, Hata N, O’Donnell LJ, Grimson WE, Jolesz FA, Black PM, Wells WM. An integrated visualization system for surgical planning and guidance using image fusion and an open MR. J Magn Reson Imaging. 2001;13(6):967–75.
A surgical guidance and visualization system is presented, which uniquely integrates capabilities for data analysis and on-line interventional guidance into the setting of interventional MRI. Various pre-operative scans (T1- and T2-weighted MRI, MR angiography, and functional MRI (fMRI)) are fused and automatically aligned with the operating field of the interventional MR system. Both pre-surgical and intra-operative data may be segmented to generate three-dimensional surface models of key anatomical and functional structures. Models are combined in a three-dimensional scene along with reformatted slices that are driven by a tracked surgical device. Thus, pre-operative data augments interventional imaging to expedite tissue characterization and precise localization and targeting. As the surgery progresses, and anatomical changes subsequently reduce the relevance of pre-operative data, interventional data is refreshed for software navigation in true real time. The system has been applied in 45 neurosurgical cases and found to have beneficial utility for planning and guidance. J. Magn. Reson. Imaging 2001;13:967-975.
Ruiz-Alzola J, Kikinis R, Westin C-F. Detection of point landmarks in multidimensional tensor data. Signal Processing. 2001;81(10):2243–2247. doi:10.1016/S0165-1684(01)00100-1
This paper describes a unified approach to the detection of point landmarks-whose neighborhoods convey discriminant information-including multidimensional scalar, vector, and higher-order tensor data. The method is based on the interpretation of generalized correlation matrices derived from the gradient of tensor functions, a probabilistic interpretation of point landmarks, and the application of tensor algebra. Results on both synthetic and real tensor data are presented.
Friman O, Cedefamn J, Lundberg P, Borga M, Knutsson H. Detection of neural activity in functional MRI using canonical correlation analysis. Magn Reson Med. 2001;45(2):323–30.
A novel method for detecting neural activity in functional magnetic resonance imaging (fMRI) data is introduced. It is based on canonical correlation analysis (CCA), which is a multivariate extension of the univariate correlation analysis widely used in fMRI. To detect homogeneous regions of activity, the method combines a subspace modeling of the hemodynamic response and the use of spatial relationships. The spatial correlation that undoubtedly exists in fMR images is completely ignored when univariate methods such as as t-tests, F-tests, and ordinary correlation analysis are used. Such methods are for this reason very sensitive to noise, leading to difficulties in detecting activation and significant contributions of false activations. In addition, the proposed CCA method also makes it possible to detect activated brain regions based not only on thresholding a correlation coefficient, but also on physiological parameters such as temporal shape and delay of the hemodynamic response. Excellent performance on real fMRI data is demonstrated. Magn Reson Med 45:323-330, 2001.
Lorigo LM, Faugeras OD, Grimson WE, Keriven R, Kikinis R, Nabavi A, Westin C. CURVES: curve evolution for vessel segmentation. Med Image Anal. 2001;5(3):195–206.
The vasculature is of utmost importance in neurosurgery. Direct visualization of images acquired with current imaging modalities, however, cannot provide a spatial representation of small vessels. These vessels, and their branches which show considerable variations, are most important in planning and performing neurosurgical procedures. In planning they provide information on where the lesion draws its blood supply and where it drains. During surgery the vessels serve as landmarks and guidelines to the lesion. The more minute the information is, the more precise the navigation and localization of computer guided procedures. Beyond neurosurgery and neurological study, vascular information is also crucial in cardiovascular surgery, diagnosis, and research. This paper addresses the problem of automatic segmentation of complicated curvilinear structures in three-dimensional imagery, with the primary application of segmenting vasculature in magnetic resonance angiography (MRA) images. The method presented is based on recent curve and surface evolution work in the computer vision community which models the object boundary as a manifold that evolves iteratively to minimize an energy criterion. This energy criterion is based both on intensity values in the image and on local smoothness properties of the object boundary, which is the vessel wall in this application. In particular, the method handles curves evolving in 3D, in contrast with previous work that has dealt with curves in 2D and surfaces in 3D. Results are presented on cerebral and aortic MRA data as well as lung computed tomography (CT) data.