Publications by Year: 2002

2002

Niznikiewicz MA, Shenton ME, Voglmaier M, Nestor PG, Dickey CC, Frumin M, Seidman LJ, Allen CG, McCarley RW. Semantic dysfunction in women with schizotypal personality disorder.. Am J Psychiatry. 2002;159(10):1767–74.
OBJECTIVE: This study examined whether early or late processes in semantic networks were abnormal in women with a diagnosis of schizotypal personality disorder. The N400 component of the EEG event-related potentials was used as a probe of semantic processes. METHOD: Word pairs were presented with short and long stimulus-onset asynchronies to investigate, respectively, early and late semantic processes in 16 women with schizotypal personality disorder and 15 normal female comparison subjects. Event-related potentials were recorded in response to the last words in a pair. RESULTS: With the short stimulus-onset asynchrony, the N400 amplitude was less negative in the schizotypal personality disorder group than in the normal comparison group. No group differences were found with the long stimulus-onset asynchrony. CONCLUSIONS: The finding of a less negative than normal N400 amplitude with the short stimulus-onset asynchrony in women with schizotypal personality disorder supports the hypothesis that persons with this disorder evince an overactivation of semantic networks. The absence of group differences with the long stimulus-onset asynchrony, which is primarily sensitive to processes involved in context integration, suggests that in this group of schizotypal personality disorder subjects, additional demands on working memory may be necessary to bring out the semantic dysfunction.
Anderson JE, Wible CG, McCarley RW, Jakab M, Kasai K, Shenton ME. An MRI study of temporal lobe abnormalities and negative symptoms in chronic schizophrenia.. Schizophr Res. 2002;58(2-3):123–34.
Previous magnetic resonance imaging (MRI) studies have reported various subtle brain abnormalities in schizophrenic patients, including temporal lobe abnormalities, which are of particular interest given the role of this brain region in auditory and language processing, and the characteristic deficits in these processes in schizophrenia. Subjects in this study were 16 male patients diagnosed with chronic schizophrenia and 15 healthy male comparison subjects. These patients were characterized by negative symptoms. High spatial resolution coronal MRI 1.5-mm-thick slices were used to measure the gray matter volume of the superior temporal gyrus, anterior and posterior amygdala/hippocampal complex, and parahippocampal gyrus. Patients, relative to normal comparison subjects, evinced a reduction of gray matter volume in bilateral superior temporal gyri and anterior amygdala/hippocampal complex. The reduction in gray matter of the superior temporal gyrus in patients with schizophrenia is consistent with previous findings, and is noteworthy in that it was found in this group of patients with predominantly negative symptoms. The reduction in the anterior amygdala/hippocampal complex was an additional temporal lobe finding. These results underscore the role of temporal lobe structures in the pathophysiology of schizophrenia.
Hirose M, Bharatha A, Hata N, Zou KH, Warfield SK, Cormack RA, D\textquoterightAmico A, Kikinis R, Jolesz FA, Tempany CMC. Quantitative MR imaging assessment of prostate gland deformation before and during MR imaging-guided brachytherapy.. Acad Radiol. 2002;9(8):906–12.
RATIONALE AND OBJECTIVES: The authors performed this study to document the deformations that occur between pretreatment magnetic resonance (MR) imaging and intraoperative MR imaging during brachytherapy. MATERIALS AND METHODS: MR images obtained at 1.5 and 0.5 T in 10 patients with prostate cancer were analyzed for changes in the shape and substructure of the prostate. Three-dimensional models of the prostate were obtained. The authors measured anteroposterior dimension; total gland, peripheral zone, and central gland volumes; transverse dimension; and superoinferior height. RESULTS: Gland deformations were seen at visual inspection of the three-dimensional models. The anteroposterior dimension of the total gland, central gland, and peripheral zone increased from 1.5- to 0.5-T imaging (median dimension, 4.9, 1.5, and 1.8 mm, respectively), and the increase was greatest in the peripheral zone (P .05, all comparisons). There was a decrease in the transverse dimension from 1.5- to 0.5-T imaging (median, 4.5 mm; P .005). The total gland volume and the superoinferior height did not show a statistically significant change. CONCLUSION: There were significant deformations in the shape of the prostate, especially in the peripheral zone, between the two imaging studies. The likely causes of the shape change are differences in rectal filling (endorectal coil used in 1.5-T studies vs obturator in 0.5-T studies) and/or changes in patient position (supine vs lithotomy). These findings suggest that pretreatment images alone may not be reliable for accurate therapy planning. It may be useful to integrate pre-and intraoperative data.
Restricted diffusion of water in a highly concentrated w/o emulsion was studied using pulsed field gradient spin echo techniques. The standard two-pulse version of this technique, suitable for analysis in the time domain, fails to investigate the short time-scale for diffusion inside a single emulsion droplet with radius 0.7 microm. With a pulse-train technique, originally introduced by Callaghan and Stepisnik, shorter time-scales are accessible. The latter approach is analyzed in the frequency domain and yields frequency dependent diffusion coefficients. Predictions for the outcome of the experiment were calculated in the time domain using the Gaussian phase distribution and the pore hopping formalism expressions for the echo attenuation. The results of these calculations were transformed to the frequency domain via a numerical inverse integral transform in order to compare with the experimental results.
Lee CU, Shenton ME, Salisbury DF, Kasai K, Onitsuka T, Dickey CC, Yurgelun-Todd D, Kikinis R, Jolesz FA, McCarley RW. Fusiform gyrus volume reduction in first-episode schizophrenia: a magnetic resonance imaging study.. Arch Gen Psychiatry. 2002;59(9):775–81.
BACKGROUND: The fusiform gyrus (occipitotemporal gyrus) is thought to be critical for face recognition and may possibly be associated with impaired facial recognition and interpretation of facial expression in schizophrenia. of postmortem studies have suggested that fusiform gyrus volume is reduced in schizophrenia, but there have been no in vivo structural studies of the fusiform gyrus in schizophrenia using magnetic resonance imaging. METHODS: High-spatial resolution magnetic resonance images were used to measure the gray matter volume of the fusiform gyrus in 22 patients with first-episode schizophrenia (first hospitalization), 20 with first-episode affective psychosis (mainly manic), and 24 control subjects. RESULTS: Patients with first-episode schizophrenia had overall smaller relative volumes (absolute volume/intracranial contents) of fusiform gyrus gray matter compared with controls (9%) and patients with affective psychosis (7%). For the left fusiform gyrus, patients with schizophrenia showed an 11% reduction compared with controls and patients with affective psychosis. Right fusiform gyrus volume differed in patients with schizophrenia only compared with controls (8%). CONCLUSION: Schizophrenia is associated with a bilateral reduction in fusiform gyrus gray matter volume that is evident at the time of first hospitalization and is different from the presentation of affective psychosis.
Salisbury DF, Desantis MA, Shenton ME, McCarley RW. The effect of background noise on P300 to suprathreshold stimuli.. Psychophysiology. 2002;39(1):111–5. doi:10.1017/S0048577202010223
Both the amplitude and latency of P300 vary with changes in stimulus parameters. Stimuli at intensities or pitch separations near threshold evoke a smaller and later P300. P300 is also affected by extraneous stimulus parameters in tasks where stimulus frequency separation is large and stimuli are well above intensity thresholds. For example, the presence of background white noise when tones are suprathreshold and easily detectable has been reported to increase P300 latency. However, the effects of background masking noise on P300 amplitude and scalp topography have not been reported. Subjects performed an oddball task both in the presence and in the absence of background noise. Performance accuracy was unaffected by background noise. P300 showed latency increases when noise was present, but P300 peak amplitude was unaffected. P300 scalp topography was stable across both conditions. P300 latency is affected by background noise, even when performance is not, but amplitude and amplitude topography remain unaffected.
Shenton ME, Gerig G, McCarley RW, ekely G abor S, Kikinis R. Amygdala-hippocampal shape differences in schizophrenia: the application of 3D shape models to volumetric MR data.. Psychiatry Res. 2002;115(1-2):15–35.
Evidence suggests that some structural brain abnormalities in schizophrenia are neurodevelopmental in origin. There is also growing evidence to suggest that shape deformations in brain structure may reflect abnormalities in neurodevelopment. While many magnetic resonance (MR) imaging studies have investigated brain area and volume measures in schizophrenia, fewer have focused on shape deformations. In this MR study we used a 3D shape representation technique, based on spherical harmonic functions, to analyze left and right amygdala-hippocampus shapes in each of 15 patients with schizophrenia and 15 healthy controls matched for age, gender, handedness and parental socioeconomic status. Left/right asymmetry was also measured for both shape and volume differences. Additionally, shape and volume measurements were combined in a composite analysis. There were no differences between groups in overall volume or shape. Left/right amygdala-hippocampal asymmetry, however, was significantly larger in patients than controls for both relative volume and shape. The local brain regions responsible for the left/right asymmetry differences in patients with schizophrenia were in the tail of the hippocampus (including both the inferior aspect adjacent to parahippocampal gyrus and the superior aspect adjacent to the lateral geniculate nucleus and more anteriorly to the cerebral peduncles) and in portions of the amygdala body (including the anterior-superior aspect adjacent to the basal nucleus). Also, in patients, increased volumetric asymmetry tended to be correlated with increased left/right shape asymmetry. Furthermore, a combined analysis of volume and shape asymmetry resulted in improved differentiation between groups. Classification function analyses correctly classified 70% of cases using volume, 73.3% using shape, and 87% using combined volume and shape measures. These findings suggest that shape provides important new information toward characterizing the pathophysiology of schizophrenia, and that combining volume and shape measures provides improved group discrimination in studies investigating brain abnormalities in schizophrenia. An evaluation of shape deformations also suggests local abnormalities in the amygdala-hippocampal complex in schizophrenia.
Schreyer AG, Herfarth H, Kikinis R, Seitz J, Schölmerich J, Geissler A, Feuerbach S. 3D modeling and virtual endoscopy of the small bowel based on magnetic resonance imaging in patients with inflammatory bowel disease.. Invest Radiol. 2002;37(9):528–33. doi:10.1097/01.RLI.0000024682.72420.A8
RATIONALE AND OBJECTIVES: Small bowel MRI (MR imaging) is a new imaging modality that excellently depicts small intestine pathology in patients with inflammatory bowel disease. Virtual endoscopy based on sectional imaging is a recently introduced technique to create endoscopy like views. The aim of this study was to evaluate the feasibility of virtual small bowel endoscopy based on MR imaging in patients with Crohn disease. MATERIALS AND METHODS: Thirty consecutive patients with Crohn disease were scanned after oral application of pineapple juice for contrasting the small bowel. Dedicated high resolution T1 weighted 3D-FLASH sequences with fat suppression were used for volume scanning. Volume-rendered 3D models of the small bowel were created and virtual endoscopy was performed. The feasibility and quality of this new visualization method was assessed. RESULTS: In nine of 30 patients virtual endoscopy was considered as good quality (flight through the entire small bowel was possible, typical folds were revealed). In 18 patients fair quality (at least 4/5 of the small bowel were depicted adequately) was assessed. In three of 30 patients virtual endoscopy was not sufficiently possible because of inadequate bowel filling or breathing artifacts. Three fistulae diagnosed on 2D MRI were visualized on the virtual endoscopic view. CONCLUSION: Virtual endoscopy of the small bowel is feasible based on high resolution MR imaging. Vivid insight views and 3D models provide an interesting addition to sectional MR findings.
Fielding JR, Hoyte LX, Okon SA, Schreyer A, Lee J, Zou KH, Warfield S, Richie JP, Loughlin KR, O\textquoterightLeary MP, et al. Tumor detection by virtual cystoscopy with color mapping of bladder wall thickness.. J Urol. 2002;167(2 Pt 1):559–62.
PURPOSE: We determine the value of color mapping of bladder wall thickness for detection of tumor as a component of virtual cystoscopy. MATERIALS AND METHODS: A total of 31 subjects with hematuria and/or a history of bladder tumor underwent helical computerized tomography of the pelvis after distention of the bladder with air. Three-dimensional (D) models were constructed, and thickness of the wall was color mapped according to a fixed and validated mm. scale. Axial source images and 3-D models were reviewed and graded for the presence of wall thickening. A comparison was made with findings on conventional cystoscopy in 31 patients and pathological specimen in 13. RESULTS: Compared with conventional cystoscopy, the analysis of axial image yielded a sensitivity of 0.80, specificity 0.90, positive predictive value 0.80 and negative predictive value 0.90 for the presence of tumor. Examination of color mapped 3-D renderings resulted in 0.83, 0.36, 0.42 and 0.71, respectively. CONCLUSIONS: Thin axial computerized tomography of the air distended bladder shows promise as a potential screening tool for bladder cancer. The low specificity of color mapped 3-D renderings makes the technique inappropriate for screening. It may valuable for guiding urologists to additional suspicious sites in a patient with a known tumor.
Frumin M, Golland P, Kikinis R, Hirayasu Y, Salisbury DF, Hennen J, Dickey CC, Anderson M, Jolesz FA, Grimson EL, et al. Shape differences in the corpus callosum in first-episode schizophrenia and first-episode psychotic affective disorder.. Am J Psychiatry. 2002;159(5):866–8.
OBJECTIVE: The corpus callosum, the largest white matter tract in the brain, is a midline structure associated with the formation of the hippocampus, septum pellucidum, and cingulate cortex, which have been implicated in the pathogenesis of schizophrenia. Corpus callosum shape deformation, therefore, may reflect a midline neurodevelopmental abnormality. METHOD: Corpus callosum area and shape were analyzed in 14 first-episode psychotic patients with schizophrenia, 19 first-episode psychotic patients with affective disorder, and 18 normal comparison subjects. RESULTS: No statistically significant corpus callosum area differences between groups were found, but there were differences in the structure’s shape between the patients with schizophrenia and the comparison subjects. A correlation between width and angle of the corpus callosum was found in patients with affective disorder. CONCLUSIONS: Corpus callosum shape abnormalities in first-episode psychotic patients with schizophrenia may reflect a midline neurodevelopmental abnormality.